Dell iDRAC Monitoring
Collect and monitor the general performance Metrics of Dell Server using SNMP Protocol.
Protocol: SNMP
Pre-monitoring steps
- The target Dell server supports the SNMP protocol.
- The iDRAC (Integrated Dell Remote Access Controller) has been configured with a network interface, allowing access to the SNMP port.
- SNMP community string or user credentials have been configured with appropriate permissions.
These are basic checks you can follow, and for further details on enabling and configuring SNMP on Dell iDRAC, you can consult the specific user manual of the Dell server.
Configuration Parameters
| Parameter Name | Parameter Description |
|---|---|
| Target Host | The IPv4, IPv6, or domain name of the monitored peer. Note: without protocol header (e.g., https://, http://). |
| Port | The port number of the server SNMP, default is 161. |
| SNMP Version | Choose between SNMPv1, SNMPv2c, or SNMPv3 |
| SNMP Community | SNMP community for v1 v2c |
| Username | SNMP username for v3 |
| Context Name | SNMP contextName for v3 |
| Auth Password | SNMP authPassword for v3 |
| Auth Encryption | Authentication encryption method for v3 (MD5 or SHA1) |
| Priv Password | SNMP privPassphrase for v3 |
| Priv Encryption | Privacy encryption method for v3 (DES or AES128) |