Skip to main content
Version: v1.6.x

IPMI2 Monitoring

Collect and monitor the general performance Metrics of Server using IPMI2.

Protocol: IPMI

Pre-monitoring steps

  1. The target server supports the IPMI2 protocol.
  2. The BMC (Baseboard Management Controller) has been configured with a network interface, allowing access to the IPMI port.
  3. User accounts have been configured, and appropriate permissions have been assigned to the accounts.

These are basic checks you can follow, and for further details on enabling and configuring IPMI over LAN, you can consult the specific user manual of the server manufacturer.

Configuration Parameters

Parameter NameParameter Description
Target HostThe IPv4, IPv6, or domain name of the monitored peer. Note: without protocol header (e.g., https://, http://).
PortThe port number of the server IPMI over LAN, default is 623.
UsernameIPMI user name
PasswordIPMI password

Collected Metrics

Metric Set: Chassis

Metric NameUnitMetric Description
System PowernoneCurrent Power State. Power is on.
Power OverloadnonePower overload. System shutdown because of power overload condition.
Power InterlocknonePower Interlock.
Main Power FaultnonePower fault. Fault detected in main power subsystem.
Power Control FaultnonePower control fault. Controller attempted to turn system power on or off, but systemdid not enter desired state.
Power Restore PolicynonePower restore policy.
Last Power EventnoneLast Power Event.
Cooling/Fan FaultnoneCooling/fan fault detected.
Drive FaultnoneDrive Fault.
Front-Panel LockoutnoneFront Panel Lockout active (power off and reset via chassispush-buttons disabled.)

Metric Set: Sensor

Metric NameUnitMetric Description
Sensor IDnoneSensor ID.
Entity IDnoneIndicates the physical entity that the sensor is monitoring or is otherwiseassociated with the sensor.
Sensor TypenoneSensor Type.
Sensor ReadingnoneCurrent Sensor Reading.