Skip to main content
Version: v1.7.x

Dell iDRAC Monitoring

Collect and monitor the general performance Metrics of Dell Server using SNMP Protocol.

Protocol: SNMP

Pre-monitoring steps

  1. The target Dell server supports the SNMP protocol.
  2. The iDRAC (Integrated Dell Remote Access Controller) has been configured with a network interface, allowing access to the SNMP port.
  3. SNMP community string or user credentials have been configured with appropriate permissions.

These are basic checks you can follow, and for further details on enabling and configuring SNMP on Dell iDRAC, you can consult the specific user manual of the Dell server.

Configuration Parameters

Parameter NameParameter Description
Target HostThe IPv4, IPv6, or domain name of the monitored peer. Note: without protocol header (e.g., https://, http://).
PortThe port number of the server SNMP, default is 161.
SNMP VersionChoose between SNMPv1, SNMPv2c, or SNMPv3
SNMP CommunitySNMP community for v1 v2c
UsernameSNMP username for v3
Context NameSNMP contextName for v3
Auth PasswordSNMP authPassword for v3
Auth EncryptionAuthentication encryption method for v3 (MD5 or SHA1)
Priv PasswordSNMP privPassphrase for v3
Priv EncryptionPrivacy encryption method for v3 (DES or AES128)

Collected Metrics

Metric Set: System Status

Metric NameUnitMetric Description
Global System StatusnoneOverall status of the system
System LCD StatusnoneStatus of the system LCD
Global Storage StatusnoneOverall status of the storage subsystem
System Power StatenoneCurrent power state of the system
System Power Up TimedayTime since the system was last powered on

Metric Set: Power Supply

Metric NameUnitMetric Description
IndexnoneIndex of the power supply
NamenoneName/Location of the power supply
WattageWOutput wattage of the power supply
TypenoneType of the power supply (Linear, Switching, Battery, etc.)
StatusnoneCurrent status of the power supply

Metric Set: Cooling Devices

Metric NameUnitMetric Description
IndexnoneIndex of the cooling device
NamenoneName/Location of the cooling device
TypenoneType of the cooling device (Fan, Blower, Heat Pipe, etc.)
ReadingRPMCurrent rotation per minute reading
StatusnoneCurrent status of the cooling device

Metric Set: Temperature Sensors

Metric NameUnitMetric Description
IndexnoneIndex of the temperature sensor
NamenoneName/Location of the temperature sensor
Reading°CCurrent temperature reading
StatusnoneCurrent status of the temperature sensor

Metric Set: Voltage Sensors

Metric NameUnitMetric Description
IndexnoneIndex of the voltage sensor
NamenoneName/Location of the voltage sensor
ReadingVCurrent voltage reading
TypenoneType of voltage (3.3V, 5V, 12V, etc.)
StatusnoneCurrent status of the voltage sensor

Metric Set: Memory Devices

Metric NameUnitMetric Description
IndexnoneIndex of the memory device
NamenoneName/Location of the memory device
TypenoneType of memory (DDR, DDR2, DDR3, DDR4, etc.)
SizeGSize of the memory device
StatusnoneCurrent status of the memory device

Metric Set: Processors

Metric NameUnitMetric Description
IndexnoneIndex of the processor
NamenoneName/Location of the processor
SpeedMHzCurrent speed of the processor
FamilynoneFamily of the processor (Pentium, Xeon, Core i7, etc.)